Options
|
Option
|
Description
|
|
/ATE |
No front panel control or display. Analogue interface
fitted as standard. |
|
/AI 5 |
0 5V analogue interface for control and
measurement |
|
/AI 10 |
0 10V analogue interface for control and
measurement |
|
/ATI 5 |
Isolated 0 5V analogue interface for control and
measurement |
|
/ATI 10 |
Isolated 0 10V analogue interface for control and
measurement |
|
/LT |
IEEE 488.2 interface with both listener and talker
functions. |
|
/LTRS |
RS 232 interface with listener and talker functions. |
|
/LT + LTRS |
IEEE 488.2 and RS232 interface with both
listener and talker functions. |
|
/LTRS485 |
RS485 interface with listener and talker functions |
|
/CAN |
CAN interface with listener and talker functions |
|
/USB |
USB interface with both listener and talker functions |
|
/WIPC |
90-264Vac input with active PFC (only available for
500W/750W units) |
|
/PFCX |
185 - 264Vac input with active PFC (only available
for 800W & 1 - 4kW |
|
/PFCZ |
90 - 135Vac input with active PFC (only available for
800W & 1 - 4kW) |
|
/3P |
3 * 400VAC input for 2kW to 12kW units |
|
/3P + N |
3 * 400VAC input + neutral (standard for units 4 -
12kW) |
|
/R |
Constant resistance mode (on units => 800W) |
|
/P |
Constant power mode (on units => 800W) |
|
/KFZ12 |
Output follows a 12Vdc automotive cranking curve |
|
/KFZ24 |
Output follows a 24Vdc automotive cranking curve |
|
/KFZXX |
Output follows a user specified curve |
|
/OCP |
Adjustable over current protection in addition to the
standard current limit |
|
/AF |
Power output on the front panel (satandard 500W/750W) |
|
/AR |
Power output on the rear panel (standard => 1kW) |
|
|
Technical Data
|
|
Input voltage (500W - 3kW Output) |
230VAC ±10% |
|
Input voltage (Output => 4kW) |
3 x 400VAC ±10% |
|
Input frequency |
47 - 63 Hz |
|
Insulation (input/output) |
3000 VAC |
|
Power Factor Correction |
0.98 |
|
Typical Efficiency |
85% |
|
Voltage Regulation |
±0.05% + 2mV |
|
Current Regulation |
±0.1% + 2mA |
|
Response Time (10% - 90%) |
<0.5mS |
|
Over Voltage Protection |
0 to 110% Vmax |
|
Ripple |
<0.2% RMS |
|
Stability |
0.05% |
|
Operating temperature |
0 - 50° C |
|
Storage temperature |
-45° C to +85° C |
|
Temperature coefficient |
0.02% per °C |
|
Derating 50°C - 70°C |
-2% per °C |
|
Harmonics |
EN61000-3-2 A14 |
|
Safety |
EN60950 |
|
Emission |
EN61000-6-4 |
|
Immunity |
EN61000-6-2 |
|
Protection |
OC / OV / OT / OP |
|
Remote Sense (<35V) |
2Vmax |
|
Remote Sense (>35V) |
5Vmax |
|
Isolation Class |
1 |
|
Computer interface resolution |
12 bit |
|
Cooling (500W & 750W) |
Front to back |
|
Cooling (1kW) |
Back to back |
|
Cooling (2 - 12kW) |
Front to back |
|
Vibration |
10 - 55Hz / 1min/ 2G XYZ |
|
Shock |
Less than 20G |
|
Case Sizes 500W & 750W (W x H x D) |
0.5 * 19" x 2U x 360mm |
|
Case Sizes 1kW - 12kW (W x H x D) |
19" x H x 434.5mm |